Features

  • 24 channels available as inputs or outputs
  • Programmable for Input (voltage or contact sensing) or Output (current source, sink or push-pull) per channel/bank
  • Ability to current share*, by connecting multiple outputs in parallel, to sink/source up to 2 A per bank
  • Ability to handle high inrush current loads (for example, two #327 incandescent lamps in parallel)
  • Supports ‘dual turn-on’ (series channel output) applications (for example, dual series ‘key’ missile launch control)
  • Programmable debounce circuitry with selectable time delay eliminates false signals resulting from relay contact bounce
  • Built-In-Test runs in background constantly monitoring system health for each channel
  • Ability to sense broken input connection and if input is shorted to +V or to ground
  • Ability to read I/O voltage and output current for improved diagnostics (indicates if load is connected)